Skip to main content
Brochure

Commercial fleet fuelling

Commercial Diesel Fuel Pumps

Fueltek supplies commercial diesel pumping and dispensing configurations for organisations that refuel vehicles, plant or equipment onsite.

The right pump is selected around fuel demand, vehicle access, dispensing rate, metering, control and the way transaction data must be recorded.

Fueltek FT4000AP commercial diesel fuel dispenser

Choosing the pump

Hardware Diesel pumps and dispensers.

Fueltek pump configurations include 50, 70, 90, 150 and 180 litre-per-minute options. Availability depends on the selected product and final site specification.

Retain compatible pumps: FT4000

FT4000 control terminal
Separate control; connected pumps provide dispensing.

FT4000 provides a separate access-control terminal and can control up to four compatible pumps simultaneously. It adds authorisation and transaction recording around the retained equipment; the connected pump and fuel path determine the dispensing rate.

Explore FT4000 →Compare retained and integrated equipment

One integrated pump: FT4000AP

FT4000AP integrated dispenser
One cabinet combines the primary pump, metering and control.

FT4000AP combines an internal pump, meter and fuel-management terminal, with control for up to three compatible external pumps. Flow options are 50, 70 or 90 LPM, with 70 LPM standard. Delivered flow depends on the tank supply and complete dispensing arrangement.

Explore FT4000AP →Compare one and two integrated pumps

Two simultaneous pumps: Twin

FT4000AP Twin dispenser
Two independent pumping arrangements for simultaneous use.

FT4000AP Twin contains two pumps, two meters and two motors that can operate together. Review the approach and exit route for both positions, the product and access arrangement on each side, and the compatible external pumps that the installation may also need to control.

Explore FT4000AP Twin →Compare simultaneous use and higher flow

Higher-flow diesel: HSP

FT4000 HSP dispenser
A higher-flow route, with the complete fuel path assessed.

HSP is available at 90, 150 or 180 LPM, as a pump-only unit or integrated managed system. The tank supply, pipework, hose and nozzle determine the flow delivered at the vehicle. Access control and reporting depend on the configuration.

Explore FT4000 HSP →Compare HSP and integrated AP dispensing
Compare the equipment arrangement
RouteWhat provides the pumping?When to assess it
FT4000Compatible external pumps; the FT4000 is the separate control terminal.Retain serviceable pumping equipment while adding or updating managed access and fuel records.
FT4000APOne internal pump, with control for up to three compatible external pumps.A new or replacement primary managed dispenser, with any external pumps reviewed as part of the site.
FT4000AP TwinTwo integrated pumps, meters and motors that can operate together.Two vehicles or dispensing duties need to be served simultaneously, with space and supply for both positions.
FT4000 HSPA higher-flow pumping arrangement, available as pump-only or an integrated managed system.Larger fills or a higher required dispensing rate justify reviewing the tank supply, pipework, hose and nozzle together.

The number of simultaneous filling positions and the required rate at each position are separate decisions. See the full product comparison for the differences between selected models.

Inputs Fueltek needs

Specify more than litres per minute.

  • Peak and typical vehicle or plant demand
  • Fuel type and storage arrangement
  • Hose reach, vehicle approach and safe access
  • Required identification and transaction fields
  • Existing meter, pump, pipework and electrical supply
  • Whether tank monitoring and remote reporting are required

Construction and configuration

The pump range includes stainless-steel cabinets, lockable access, automatic shut-off nozzles and pulsed outputs for connection to fuel management controls. Equipment varies by model and project.

We match hydraulic, electrical, metering and control requirements to your installation, alongside the required flow rate.

A pumping unit draws from the storage arrangement; a dispenser works with a compatible pressure supply. Storage position, pipework, pressure, metering and isolation determine the required equipment.

Simultaneous filling and individual flow rate serve different requirements: two independent outlets can serve two vehicles together, while flow rate affects the dispensing time for an individual fill.

Connected site

FMO From metered issue to fuel records.

Control

Authorised dispensing

The connected fuel-control terminal associates an authorised issue with the configured user, vehicle, asset or tag.

Record

Transaction visibility

Configured fuelling entries and measured quantities become available through FMO for transaction reporting.

Stock

Tank information

TankWatch adds measured stock and delivery information alongside dispensing records where the installation includes tank monitoring.

Report

Fuel Manager Online

FMO gives authorised teams browser-based visibility of the connected fuel point and configured sites.

Example FMO screens · Views and records depend on the connected equipment and account permissions. Select an image to view it full size.

Fueltek FMO Reports screen showing transaction, totals, stock, fleet and automated report choices
Records from managed dispensing

FMO offers reporting for metered issues recorded through a compatible connected fuel-control terminal.

Fueltek FMO ID Devices screen showing vehicle, driver, fueller and trailer records with an event list
Users, vehicles and fuel records

Configured identity records connect the authorised user or vehicle to the fuel issue; these functions require managed dispensing.

Common questions

The right pump for your operating demand.

Which pump speed should a commercial fleet choose?

It depends on vehicle tank sizes, peak queue, hose and pipework, fuel storage and the duty of the installation. We assess those inputs before confirming a pump configuration.

Can a diesel pump connect to fuel management?

Pulsed-output configurations can connect compatible pumps to fuel management controls. The connection depends on the pump model and existing site equipment.

Can two vehicles refuel at once?

The FT4000AP Twin is the relevant route to assess where two pumping duties or simultaneous operation are required.

Plan the complete site

Plan around demand, layout and existing equipment.

Photographs, model details, vehicle types, peak demand and reporting requirements help us assess the right commercial pump arrangement for your site.

Technical detail

Pump safety, metering and the installation

EN 13617-1 concerns the safety of metering pumps and dispensers. Its application depends on the equipment model and intended use.

EN 13617-1

BSI’s current 2021 edition addresses safety requirements for metering pumps, dispensers and remote pumping units within its scope. It does not set metering-performance requirements. Read the BSI scope.

Meter accuracy

Meter accuracy depends on the meter specification and test conditions. EN 13617-1 concerns pump and dispenser safety, rather than measurement accuracy.

Hazardous-area documentation

Hazardous-area suitability depends on the equipment marking, certificate conditions and intended use. Manufacturing quality assurance and product certification cover different requirements.

The complete fuel path

Tank position, pipework, filtration, hose and nozzle affect delivered flow. We match the complete fuel path to the required duty.

Technical detail

What pumping and metering components do

An integrated dispenser combines several functions that are worth specifying separately.

Air separation

FT4000AP includes air separation in its pumping arrangement. This separates entrained air from the liquid path; filtration and fuel quality remain separate considerations.

Displacement metering

FT4000AP uses a four-piston displacement meter to measure issued volume. Meter calibration, user authorisation and tank stock measurement are separate functions.

Nozzle and hose

Hose reach and nozzle suitability affect how vehicles can position and refuel. Include filler location, vehicle capacity and the full refuelling process when comparing a higher-flow option.

Transaction and totalisers

An individual issue, a period total and a lifetime total answer different questions. Use the same outlet and time period when reconciling dispenser figures with software records.

Product information

FT4000 MID for diesel resale

The FT4000 MID configuration is designed for diesel resale. It is available as an integrated dispenser and fuel-management system or as a standalone pump connected to a compatible approved management system.

Metered diesel delivery

The MID configuration has a 7–70 LPM operating range, stainless-steel housing, belt-driven pumping with integral air separation and a solenoid valve. Its motor uses a 240 V single-phase supply rated at 10 A.

Hose and display

Standard equipment includes a 3.66 m steel-braided hose, automatic nozzle and safety breakaway coupling. The single-sided illuminated commercial display has 25 mm digits.

Measuring-system approval

UK Weights & Measures approval UK/0126/0241 applies to the FT4000 MID measuring-system configuration. The dispenser, meter, electronics, software and connected equipment form the approved system.

Email salessales@fueltek.co.uk WhatsApp our Sales TeamWe’re just a click away